Shofu Beautifil Flow Refills

Beautifil Flow compliments the Giomer restorative family with its flowable consistency, uniformity of shade and remarkable flexural strength while ensuring an all-round fluoride rich system, thus making it an ideal choice for lining, base and cervical abrasions. It has two distinct viscosities reflected as F02 & F10. F02 has low or minimal flow while F10 has high flow.

Flowable Direct Aesthetic Composite
1,175.00 Inclusive GST
In Stock, Swift Delivery

Shofu Beautifil Flow F02 - A1

Low Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

Out of stock

Out of stock
Add Quantity

Shofu Beautifil Flow F02 - A2

Low Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

In stock

In Stock, Swift Delivery
Add Quantity

Shofu Beautifil Flow F02 - A3

Low Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

Out of stock

Out of stock
Add Quantity

Shofu Beautifil Flow F10 - A1

High Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

Out of stock

Out of stock
Add Quantity

Shofu Beautifil Flow F10 - A2

High Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

Out of stock

Out of stock
Add Quantity

Shofu Beautifil Flow F10 - A3

High Flow Direct Aesthetic Composite

Original price was: ₹1,440.00 Current price is: ₹1,175.00. Inclusive GST

Out of stock

Out of stock
Add Quantity
1 People watching this product now!

Beautifil Flow compliments the Giomer restorative family with its flowable consistency, uniformity of shade and remarkable flexural strength while ensuring an all-round fluoride rich system, thus making it an ideal choice for lining, base and cervical abrasions. It has two distinct viscosities reflected as F02 & F10. After several years of research into the S-PRG Technology (Surface Pre-Reacted) BEAUTIFIL Flow was developed to give you two distinctive viscosities F02 (Low Flow) and F10 (High Flow) while maintaining the same aesthetics, physical properties, particle size and filler load.

  • A Variety of minimal lesions such as class I, III & V cavities (minimal intervention).
  • Small, non-occlusal stress-bearing restorations in posterior teeth.
  • Root caries & Enamel defects
  • Deciduous dentition
  • Base & Liner under Direct restorations
  • Shade adjustment & modification of direct restorations
  • Blocking undercuts
  • Repair ceramic or composite veneers
  • Adhesive cementation of Laminate veneers
  • Ideal for areas where Accessibility is minimal such as Gingival Box of Class II cavities
  • A Variety of minimal lesions such as class I – III & V cavities (minimal intervention)
  • Root caries & Enamel defects
  • Deciduous dentition
  • Base & Liner under Direct restoration
  • Shade adjustment & modification of direct restoration
  • Blocking undercuts
  • Repair of ceramic or composite veneers
  • Adhesive cementation of Laminate veneers
  • Can also be used as pit and fissure sealant
  • High wear resistance and long-term stability
  • Sustainable fluoride release and recharge
  • Remarkable radiopacity
  • Natural light diffusion
  • Innovative syringe design with 360º rotary finger grip
  • Do not use this product on patients with known allergies to this material and/or methacrylate monomer.
  • Operators with known allergies to this material and/or methacrylate monomer must not use this product.
  • If any inflammation or other allergic reactions occur on either the patient or operator, immediately discontinue use and seek medical advice.
  • Use medical (dental) gloves and protective glasses to avoid sensitization to this product. In case of accidental contact with oral soft tissue or skin, immediately blot with alcohol moistened cotton ball, and rinse with plenty of water. Medical (dental) gloves provide some protection against direct contact with this material; however some monomers can penetrate through the gloves very quickly to reach the skin. Therefore, should this material contact even the gloves, immediately remove them and wash hands with plenty of water.
  • In case of contact with eyes, immediately flush the eyes with plenty of water and seek medical advice.
  • This product is intended for use by dental professionals only.

  • Thoroughly clean the tooth surface to remove plaque.
  • Select appropriate shade using a shade guide while the tooth is still moist.
  • Prepare the cavity following the conventional method.
  • Isolate with a rubber dam.
  • In the case where the affected area is close to the pulp,cap the pulp with calcium hydroxide etc.
  • Do not use eugenol containing materials since they might inhibit polymerization or adhesion of the material.
  • Apply dentin adhesive following the manufacturer’s instructions for use.
  • Follow the instructions to attach the BEAUTIFIL Needle Tip provided: 1. Pull off the shield cap while turning it slowly. (Fig.A); 2. Attach the needle tip by turning it clockwise until it is securely attached. (Fig.B)
  • Wear clean medical (dental gloves) when replacing the needle tip.
  • Apply necessary amount of BEAUTIFIL Flow directly into the cavity and create the shape desired. BEAUTIFIL Flow may also be extruded onto a paper pad to be applied into the cavity with a suitable instrument.
  • When storing these materials in a refrigerator, allow them to reach room temperature before use.
  • The paste dispensed onto the paper pad should be shielded from ambient light by light-shielding cover to avoid unintended polymerization of the material.
  • Needle tips should be used for only one patient and then discarded at the end of the procedure to avoid cross contamination.
  • Light-cure using a dental light-curing unit.
  • When the cavity is deep, incremental filling and lightcuring not exceeding 2 mm is recommended.
  • When the cavity surface is large, light-cure in segments.
  • Dental light-curing unit and light-curing time.
Light Curing Unit Curing Time
Halogen 30 sec
LED 10 sec

Halogen light-curing unit: Wavelength: 400-500 nm; Light intensity: ? 500 mW/cm2

LED light-curing unit: Wavelength: 440-490 nm; Light intensity: ? 1,000 mW/cm2

  • Use a dental light-curing unit having specifications equivalent to those described above. When using the one having performance other than these recommendations, follow the instructions of each unit to light-cure BEAUTIFIL Flow properly.
  • Operators must use protective glasses or light shielding plate to avoid looking directly at the curing light. Operators must also protect patients’ eyes from direct exposure to curing light.
  • Disinfect the syringe and shield cap with alcohol after each use to avoid cross-contamination. Then, tightly close the cap. Use caution to avoid including alcohol into the paste.
  • Disinfect the light-curing unit with alcohol after each use to avoid cross-contamination.
  • After light-curing, contour, finish and polish the restoration following the conventional method.
  • Base/Liner:
  • Follow all the procedures of Anterior and posterior restorations explained above.
  • Apply necessary amount of BEAUTIFIL Flow directly into the cavity and create the shape desired. BEAUTIFIL Flow may also be extruded onto a paper pad to be applied into the cavity with a suitable instrument. Light-cure the material using a dental light-curing unit (Halogen: 30 sec. or LED: 10 sec.).
  • When storing these materials in a refrigerator, allow them to reach room temperature before use.
  • The paste dispensed onto the paper pad should be shielded from ambient light by light-shielding cover to avoid unintended polymerization of the material.
  • Needle tips should be used for only one patient and then discarded at the end of the procedure to avoid cross contamination.
  • Fill direct composite resin.
  • After light-curing, contour, finish and polish the restoration following the conventional method.
  • Discard the used Needle Tip and store this product in either way of the following.
  • Attach new one. Insert the needle into the small hole on the head of the shield cap. (Fig.C)
  • Replace the shield cap securely. (Fig.D)
  • Store at room temperature (1-30 °C/ 34-86 °F). Avoid high temperatures and high humidity. Keep away from direct sunlight and any source of ignition.

A1, A2, A3, A3.5, A4 , A3O, G

A1, A2, A3, A3.5, A4, A3O, A3T

  • 2g Syringe
  • Needle Tips x 5

Delivery Details

CHECK

FAQs

Have doubts regarding this product?

No relevant questions available.
Subtotal : ₹.00
MRP : 0.00
0.00%
Item Count: 0

Payment Options

    • Experience Convenience and Trust with Our Cash on Delivery (COD) Payment Service
    • COD enabled for select products only. If all items in your cart are COD enabled, then COD service will be available on checkout. Max. cart amount applicable for COD is ₹10,000.
    • Retail and corporate net banking is accepted for all major banks. Choose your preferred account type for a seamless transaction.
    • UPI payments accepted via Google Pay, PhonePe, BHIM, Paytm, CRED UPI, Amazon Pay UPI, and more for a fast, convenient checkout experience.

Ratings & Reviews

0.0
|
0 Reviews
Customer Reviews (0)

Product is not listed you are looking for ?

Tell us by filling in details below.

Dura Deals

Also Check >>

Magic Cards - 100x100

Dura Discounts

Cancellation - 100x100

Easy Cancellation

Carton with Lense - 100x100

Genuine Products

Two Red Arrow - 100x100

7 Days Replacement